home | about us | contact us | visit us | trade enquiries | view cart
 


WF100S Wall/Window Electronic Standard fan WF100S Wall/Window Electronic Standard fan
-Standard model for remote switching.
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.

 



Price (excluding VAT):   £27.22




WF100P Wall/Window Electronic pullcord fan WF100P Wall/Window Electronic pullcord fan
-As standard model with Pullcord operation
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.

 



Price (excluding VAT):   £19.23




WF100T Wall/Window Electronic timer fan WF100T Wall/Window Electronic timer fan
-Calibrated Timer Fan XF100T easily adjustable between 1-20 minutes with the calibrated adjuster inside the fan.
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.

 



Price (excluding VAT):   £31.78




WF100A Wall/Window Electronic Fan with automatic shutters WF100A Wall/Window Electronic Fan with automatic shutters
-Fan has automatic shutters which open when extracting air and close to help stop back draft when fan is switched off
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.

 



Price (excluding VAT):   £43.18




WF100AP Wall/Window Electronic Fan with automatic shutters and pullcord WF100AP Wall/Window Electronic Fan with automatic shutters and pullcord
-Fan has automatic shutters which open when extracting air and close to help stop back draft when fan is switched off with pullcord operation
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.
 



Price (excluding VAT):   £44.64




WF100AT Wall/Window Electronic Fan with automatic shutters and timer WF100AT Wall/Window Electronic Fan with automatic shutters and timer
-Fan has automatic shutters which open when extracting air and close to help stop back draft when fan is switched off,also has a run on timer
-Extract rate 85m³hr, 23 litres per second
-British made
-Designed to exceed the 1995 Building Regulations on Ventilation (F1)
-Tested to comply with HD280/BS3456 Part 102:342 1988
-Full back up range of ventilation accessories
-2 year no quibble guarantee
-BEAB approved
-Rated to IP44
-Maximum pressure: 20 p.a. Fan speed: 2400 r.p.m.
-Sound volume: 41.0 dB(A) Maximum operating temperature 40° C.
-220-240V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and do not require an earth. All wiring must comply with current IEE regulations. A double pole isolating switch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fuse fitted. The fan must not be accessible to a person using either the shower or bath and mounted a minimum of 1.8 metres from the floor.
 